Resource Engineered Products
Resource Engineered Products
  • Home
  • Line Card
  • Products
    • Transformers >
      • Large & Medium Power Transformers
      • Small Power Transformers
      • Distribution Transformers
      • Instrument Transformers
      • Specialty Transformers
    • Capacitors >
      • High Voltage Capacitor Banks
      • Medium Voltage Capacitors
      • Low Voltage Capacitors
      • Specialty Capacitors
    • Distribution Equipment >
      • High Voltage Distribution Equipment
      • Medium Voltage Distribution Equipment
      • Low Voltage Distribution Equipment
    • Power Quality >
      • High Voltage Power Quality
      • Medium Voltage Power Quality
      • Low Voltage Power Conditioning
    • Metering & Monitoring >
      • Metering & Monitoring Devices
    • Enclosures >
      • Enclosures
  • Industries
  • About Us
  • Contact Us
  • Home
  • Line Card
  • Products
    • Transformers >
      • Large & Medium Power Transformers
      • Small Power Transformers
      • Distribution Transformers
      • Instrument Transformers
      • Specialty Transformers
    • Capacitors >
      • High Voltage Capacitor Banks
      • Medium Voltage Capacitors
      • Low Voltage Capacitors
      • Specialty Capacitors
    • Distribution Equipment >
      • High Voltage Distribution Equipment
      • Medium Voltage Distribution Equipment
      • Low Voltage Distribution Equipment
    • Power Quality >
      • High Voltage Power Quality
      • Medium Voltage Power Quality
      • Low Voltage Power Conditioning
    • Metering & Monitoring >
      • Metering & Monitoring Devices
    • Enclosures >
      • Enclosures
  • Industries
  • About Us
  • Contact Us

Metering & Monitoring & UPS Systems


Picture
PulserPlus.Net™ – REDUCES RISK OF ARC FLASH HAZARDS BY 98%! It is accepted in the electrical industry that 98% of all electrical system failures begin as ground faults. High Resistance Grounding limits the fault current so that ground faults do not develop into a more serious equipment problem or potential safety problem. With a High Resistance Grounding system:
  1. There is no need to immediately trip the system, allowing continued process operation and orderly management of downtime.
  2. Thermal damage to equipment is dramatically limited due to the low fault current.
  3. Overall plant safety is improved since the Arc Flash Hazard is reduced by 98 percent.
  4. Ground faults are easy to locate and repair, saving maintenance time and money.
Post Glover Resistors is pleased to introduce the NEW PULSERPLUS.NET high resistance grounding system, improving on an already world-class product, the patented, UL Listed PULSER PLUS PRO. The PULSERPLUS.NET carries all of the features of the PULSER PLUS PRO, and adds features that further separate this product from the rest.
Ground Fault Detection: Under voltage and under current detection and alarm
Resistor Monitoring: NEW – Sensing resistor for neutral path monitoring standard
Pulsing System: Adjustable from 10 to 50 pulses per minute allowing custom setup within your system
Password Security: NEW – Prevent unauthorized parameter and setting changes
Harmonics Filtering: Avoids nuisance tripping by measuring only fundamental frequency
Communications: NEW – Remote operation and monitoring via Ethernet and RS 232/485
Data Logging: NEW – Comprehensive data logging of all alarms and events for fault isolation and trending
Tapped Resistors: NEW – Quickly and easily change resistance taps via terminal strip
The Post Glover PULSERPLUS.NET is an excellent choice for:
Grounding applications in process industries, steel mills, pulp and paper mills, power distributors, mining operations, hospitals, and 24/7 data centers.
Limits ground fault currents to specified levels between 2 and 10 amps
Available in free-standing, wall-mount and OEM switchgear kit format
Integrated control power transformer with 50/60 Hertz rating
UL Listed.


Picture
Industrial, heavy duty AC UPS with full galvanic insulation. Designed to Supply critical AC loads with stabilized continuous supply, in the Oil & Gas, Petrochemical, Power & Utilities applications.
  • Built-in inverter transformer for DC/AC galvanic separation
  • Input Transformer for AC/DC galvanic separation and SCR rectifier for reliable operation in all mains condition
  • High personalization grade, thanks to the modular layout
  • 16 Bit microcontroller control, digital control panel with history of alarms, full set of communications options

Industrial, heavy duty Rectifier Battery Charger with full galvanic insulation. Designed to supply critical DC loads with stabilized continuous supply, in the Oil & Gas, Petrochemical, Power & Utilities applications.
  • Input Rectifier transformer for AC/DC galvanic separation.
  • Power conversion bridge with natural cooling, for the maximum reliability and reduced maintenance.
  • High personalization grade, thanks to the modular layout.
  • 16 Bit microcontroller control, digital control panel with history of alarms, full set of communications options.

Picture
Sub-metering is the most accurate and widely used method of recovering variable utility costs. It is a
proven, cost effective and easy to implement method to recover electric expenses.
Properties benefit from:
• Accurate energy monitoring, real-time energy consumption
• Ability to identify and eliminate wasted energy
• Reduced variable utility costs
• Improved net operating income
• Increased property value

Resource Engineered Products LLC -- 22020 S. Grapevine Road, West Linn, OR 97068 -- 503-699-1350